Support added October 2021
Codecs & Templates have been expanded to allow exposing commands into our dashboard UI. When these are selected they allow us to trigger commands to the device that will set certain common configuration options that we’ve chosen to expose.
Info |
---|
These options must be supported in the Codec as well as a |
...
Example (command.interval)
Code Block |
---|
[
{
"order": 0,
"label": null,
" Link to our Google Doc showing templates and testing status. |
Table of Contents |
---|
Code Block |
---|
"variables": [ { "order": 0, "label": "Reading Interval", "type": "string", "key": "command.interval", "form": "select", "min": null, "max": null, "required": true, "hide_on_setup": true, "help_texts": [{"value": "Device must be online before changing interval setting", "order": 0}], "default_value": "600", "values": [ { "label": "30 seconds", "value": "30" }, |
The key (e.g.
command.interval
) tells the codec what type of downlink command is defined/used.Displaying user friendly text is done using the label and help_texts options. Use these so that it is clear to the user what these options do when selected in our Settings UI.
See the tech doc with full details for more info: Downlink Interval Doc
...
Example (command.interval)
Code Block |
---|
[ { {"order": 0, "label": null, "labelvariables": [ "1 minute", { "valueorder": "60"0, "label": "Reading },Interval", "type": "string", { "key": "command.interval", "labelform": "2 minutesselect", "min": null, "value": "120" "max": null, }, "required": true, { "hide_on_setup": true, "labelhelp_texts": [{"value"5: minutes",Device must be online before changing interval setting", "order": 0}], "default_value": "300600", },"values": [ { "label": "10 minutes", "value": "600" }, { "label": "15 minutes", "value": "900" }, { "label": "20 minutes", "value": "1200" }, { "label": "30 minutes", "value": "1800" }, { "label": "1 hour", "value": "3600" }, { "label": "6 hours", "value": "21600" } ] } ] } ] |
Defining variables keys prefixed with “command.” allows Prometheus to pick those variables, encode unitary commands through the codec, and trigger the downlink eventually.
However the “command.” prefix will be stripped before calling the codec.
Prometheus will trigger codec with a single command for each setting changed, queuing all commands at the LNS level.
...
Notes
Note |
---|
Unless specifically required (approved?), do not add interval of less than 10 minutes. It will only lead to hardware and RMA troubles for us. If necessary we can do this as a one-off configuration by issuing downlink commands to hardware via the console, there’s no reason to expose smaller values to users in the UI. |