See the tech doc with full details for more info: Downlink Interval Doc
...
Example (command.interval)
Code Block |
---|
[
{
"order": 0,
"label": null,
"variables": [
{
"order": 0,
"label": "Reading Interval",
"type": "string",
"key": "command.interval",
"form": "select",
"min": null,
"max": null,
"required": true,
"hide_on_setup": true,
"help_texts": [{"value": "Device must be online before changing interval setting", "order": 0}],
"default_value": "600",
"values": [
{
"label": "30 seconds",
"value": "30"
},
{
"label": "1 minute",
"value": "60"
},
{
"label": "2 minutes",
"value": "120"
},
{
"label": "5 minutes",
"value": "300"
},
{
"label": "10 minutes",
"value": "600"
},
{
"label": "15 minutes",
"value": "900"
},
{
"label": "20 minutes",
"value": "1200"
},
{
"label": "30 minutes",
"value": "1800"
},
{
"label": "1 hour",
"value": "3600"
},
{
"label": "6 hours",
"value": "21600"
}
]
}
]
}
] |
Notes
Note |
---|
Unless specifically required (approved?), do not add interval of less than 10 minutes. It will only lead to hardware and RMA troubles for us. If necessary we can do this as a one-off configuration by issuing downlink commands to hardware via the console, there’s no reason to expose smaller values to users in the UI. |